Federal Aviation Administration
Locations:
Sort By: Keyword Sort:

Data Current as of: Thu, 21 Nov 2019 14:13:00 UTC

A1717/19 NOTAMR A1276/19
Q) GOOO/QNDAS/IV/BO/AE/000/999/1429N01124W200
A) GAKD B) 1911121238 C) 2002112359 EST
E) DME 'KAY' CH114X U/S. PROCEDURES VOR Z RWY 09 AND VOR Z RWY 27 
ARE PROHIBITED.
A1354/19 NOTAMN 
Q) GOOO/QFFXX/IV/NBO/A/000/999/1429N01124W005
A) GAKD B) 1909031600 C) PERM
E) READ FIRE FIGHTING VEHICLES:
1VIMP 6700L WATER + 800L FOAM 
1VIMP 91125/VMA91
1VIPP 4000L WATER + 600L FOAM +250KG POWDER
1FLYCO - 2EXTINGUISHERS 9KG -1BOTTLE 50KG POWDER
INSTEAD OF:
1VIMP 6700L WATER + 800L FOAM 
1VIPP 4000L WATER + 600L FOAM +250KG POWDER
1VIPP 4000L WATER + 400L FOAM +250KG POWDER
1FLYCO - 2EXTINGUISHERS 9KG -1BOTTLE 50KG POWDE.
MODIFY ASECNA AIP: PAGE 10AD2.5-02 TAB AD2.6 LINE 2
A0070/19 NOTAMN 
Q) GOOO/QXXXX/IV/NBO/AE/000/999/1429N01124W005
A) GAKD B) 1901171439 C) PERM
E)
SECONDARY POWER SUPPLY/SWITCH-OVER TIME:READ STANDBY POWER PROVIDED
BY ONE(1) DIESEL POWER GENERATOR 275KVA/5 SECONDES INSTEAD OF STANDBY
POWER PROVIDED BY TWO(2) DIESEL POWER GENERATORS 150KVA/5 SECONDES.
MODIFY AIP ASECNA PAGE:10AD2.5-06 TABLE GAKD AD2.15 LINE 4
A0052/19 NOTAMN 
Q) GOOO/QXXXX/IV/NBO/AE/000/999/1429N01124W005
A) GAKD B) 1901140950 C) PERM
E) HANDLING CONTACT:READ (00223)91911691 INSTEAD OF (00223)66736698.
MODIFY AIP ASECNA PAGE:10AD2-5-01 TABLE GAKD-AD2.3 ,LIGNE 9 AND PAGE
10AD2.5.02 ,TABLE GAKD-AD2.4,LINE 1
A1234/18 NOTAMN 
Q) GOOO/QFAXX/IV/NBO/A/000/999/1429N01124W005
A) GAKD B) 1808030900 C) PERM
E) AIRDROME ELEVATION/REFERENCE TEMPERATURE: READ 50M/43DEG CELSUIS
INSTEAD OF 50,25M/43DEG
MODIFY ASECNA AIP PAGE:10AD2.5-01 TABLE GAKD-AD2.2, LINE 3

  
Number of NOTAMs:  5        End of Report